AC Compressor Repair & Replacement in Terrell, TX

We check the windings, amp draw and capacitor before we call a compressor dead. A lot of the time, it isn't.

Technician measuring AC compressor amp draw with a clamp meter at an outdoor unit in Terrell, TX

The compressor is the sealed steel dome inside your outdoor unit. It pumps refrigerant through the whole system, and it's the most expensive single part in it, so “your compressor is gone” deserves a second look before anyone writes up a replacement. When a compressor won't start, very often the compressor itself is fine and the part that starts it, switches its power or protects it from heat has failed. We test the compressor before we condemn it.

Failures that look like a dead compressor

From the driveway, these all look alike: the unit may hum, the fan may or may not spin, and the house isn't cooling. We see every one of them written up as a dead compressor by someone in a hurry.

A failed run capacitor

The compressor depends on a capacitor to start and to run efficiently. When the capacitor weakens, and a Texas summer is hard on them, the compressor hums, can't turn over and shuts off on its overload a few seconds later. It's also one of the cheapest parts on an AC. Our AC repair page covers it with the other electrical failures.

A pitted or blocked contactor

The contactor is the switch that sends 240 volts to the compressor when the thermostat calls for cooling. Burned, pitted contacts can pass too little voltage for the compressor to start, and in Texas a colony of fire ants nesting in the switch can stop it closing at all. Either way the compressor never gets full power. It sits silent or hums, and it may be perfectly healthy.

A compressor that needs help starting

An older compressor, or one trying to start before the system's pressures have equalized, can need more starting torque than the run capacitor provides. A hard-start kit (a start capacitor plus a relay that drops it out once the motor is turning) supplies that extra push. On a compressor that's sound but slow to start, that's a legitimate repair. On one with a mechanical failure it buys very little time, and the amp draw and winding readings tell us which one we're looking at.

A tripped internal overload

Inside the shell, a thermal protector shuts the compressor off when it overheats, and it stays off until the compressor cools, which can take hours. Test the windings while it's still hot and they read open, exactly like a burned-out motor. That's the classic misdiagnosis. Once it's cool and running, we look for what overheated it, which is usually an outdoor coil matted with cottonwood fluff or grass clippings, a failed outdoor fan motor, or a low charge from a refrigerant leak.

Wiring, voltage and control problems

A loose or burned wire at the compressor terminals, low supply voltage on a hot afternoon, a tripped high- or low-pressure switch, or a control board that has locked the compressor out can all stop it cold. On variable-speed systems, the inverter drive that powers the compressor can fail and mimic a dead compressor too.

How we test a compressor

We start with the power off and the wires pulled from the compressor terminals. If the compressor is hot, we wait for it to cool. Then:

TestWhat's measuredWhat a failing result looks like
Winding resistanceOhms between the common, run and start terminalsAn open circuit on a cool compressor, or readings that don't add up (run-to-start should equal the other two combined)
Short to groundResistance from each terminal to the copper or shell, ideally with a megohmmeterAny path to ground. A grounded compressor usually trips the breaker and has to be replaced
Starting ampsCurrent as it tries to start, compared with LRA (locked rotor amps) on the nameplatePulls close to LRA and never comes up to speed: a locked rotor. A hard-start kit is worth trying first
Running ampsCurrent while running, compared with RLA (rated load amps) on the nameplateWell above RLA means it's fighting something (charge, airflow, voltage). Well below, with poor pressures, means it's running but not pumping
Voltage under loadSupply voltage at the unit while starting and runningA sag outside the nameplate range points to wiring or supply, not the compressor

Last, we read pressures. A compressor that runs but leaves its suction and discharge pressures close together isn't pumping. That's an internal failure, and no outside part will fix it. Anyone who calls your compressor bad should be able to show you the numbers behind it.

Told your compressor is dead? Questions worth asking

  • Were the windings tested after the compressor had cooled down?
  • What were the resistance readings, and was it checked for a short to ground?
  • Were the capacitor and contactor tested, or swapped, first?
  • Would a hard-start kit get it running, and for how long?
  • What caused the failure, and what will keep a replacement from failing the same way?
  • Is the compressor still under the manufacturer's parts warranty?

If the answers are thin, a second look costs far less than a compressor or a new system. Bring the other company's findings to a second-opinion visit, and we'll run the tests above and show you the readings, whichever way they come out.

Compressor, condensing unit or whole system

If the compressor has failed, you have three options. Which one makes sense depends mostly on the system's age, its refrigerant and its warranty.

Replace only the compressor

This makes sense when the system is fairly young, the compressor is still under the manufacturer's parts warranty, and the rest of the outdoor unit (coil, fan motor, cabinet) is in good shape. It's a substantial job: the refrigerant is recovered, the old compressor is cut out, the new one is brazed in with nitrogen flowing through the tubing, a new filter-drier goes in, and the system is pressure-tested, evacuated and recharged by weight. A new compressor shouldn't start life on the old capacitor and contactor, so those are usually replaced at the same time.

Replace the outdoor condensing unit

If the compressor's warranty has run out and the outdoor coil or fan motor is tired too, a new condensing unit costs more than a compressor alone but brings a new coil, fan and parts warranty with it. Federal rules still allow an R-410A condensing unit to be replaced on an existing R-410A system. The catch is the indoor coil: the new outdoor unit has to be a listed match for it, which our evaporator coil page explains.

Replace the whole system

When the system runs on R-22, when it's well into its second decade and the indoor coil is aging along with it, or when a burnout has contaminated everything, a new matched system is usually the better use of the money. It will generally use one of the newer A2L refrigerants; our AC replacement page covers sizing and what a good installation includes.

What the compressor warranty covers

Many major brands cover the compressor for 10 years when the equipment was registered on time, usually within 60 to 90 days of installation, and often for only 5 years when it wasn't. Terms vary by brand and model, so the serial number and the manufacturer's warranty lookup are the first stop.

A covered compressor still costs money to replace. Parts warranties typically exclude labor and refrigerant, and on a compressor job the recovery, brazing, evacuation, filter-drier and full charge make up much of the bill. Our own repair work carries a 30-day repair warranty, and you see the full written price before anything starts.

Burnout clean-up: protecting the new compressor

Not every compressor failure is clean. When a motor winding shorts and burns, it cooks the oil and leaves acid and carbon throughout the system; there's often a sharp, acrid smell the moment the system is opened. Install a new compressor into that, and the same acid goes to work on the new windings.

So after a compressor failure, we pull an oil sample and test it for acid. If it's positive, the clean-up adds a burnout-rated suction-line filter-drier and a new liquid-line drier. After a run, the oil is re-tested and driers changed until the acid is gone; then the suction drier comes out so it can't restrict flow. It can mean a return visit. Skip it, and you may be paying for a second compressor.

Garden hose rinsing dust and cottonwood off an outdoor AC condenser coil at a Terrell, TX home

Keeping a compressor alive

  • Keep the outdoor coil clear. With the power off at the outdoor disconnect, rinse cottonwood, clippings and dust off with a garden hose (not a pressure washer). A clogged coil raises the pressure and heat the compressor works against.
  • Fix refrigerant leaks instead of topping them off. A low charge leaves the compressor running hot.
  • Replace a weak capacitor when it tests low, before it fails and drags the compressor through hard starts.
  • Reset a tripped breaker once at most. Repeated resets on a shorted or locked compressor only add damage.
  • Have it tested every spring. A spring tune-up measures capacitor values and amp draw while a weak part is still a cheap fix.

Questions About AC Compressor Repair

The outdoor unit hums but nothing spins. Is that the compressor?

It might be, but a hum with no start is the classic sign of a failed capacitor, which is a far smaller repair. Turn cooling off at the thermostat instead of letting it keep trying, because a compressor straining against a bad capacitor heats up with every attempt. Reset a tripped breaker once at most; if it trips again, leave it off and book a service visit.

Another company says my compressor is shot. Should I get a second opinion?

If the diagnosis came without readings, yes. Ask what the winding resistance and ground tests showed and whether the compressor had cooled down before it was tested. Then have it re-tested on a second-opinion visit. If the compressor really has failed, you've lost little. If it hasn't, you may have kept a working system out of the scrap pile.

Is a hard-start kit a real fix or a band-aid?

That depends on why the compressor struggles. For an older compressor that's mechanically sound but slow to start, often on hot afternoons or right after a brief power interruption, a hard-start kit is a legitimate, inexpensive repair. For a compressor with a locked rotor or a failing winding, it buys days or weeks at best. Measuring amp draw and winding resistance tells you which one you have.

Can you put a new compressor in my R-22 unit?

Technically, yes. Replacement compressors for R-22 equipment still exist, and the system can be recharged with reclaimed R-22. It's rarely good value. You'd be paying for a major part, most of a day's labor and a full charge of a refrigerant that's no longer produced, on a system old enough that its coils and fan motor are likely next in line.

Does registering my AC really matter for the compressor warranty?

Often it's the difference between 10 years of parts coverage and 5. Most major manufacturers want registration within 60 to 90 days of installation, and for new-construction homes some brands count from the closing date instead. If you're not sure your system was registered, the manufacturer's website can usually check by serial number.

How long does a compressor replacement take?

Once the compressor is on hand, the replacement usually takes most of a day: recovering the refrigerant, cutting out the old compressor, brazing in the new one, then a pressure test, deep vacuum and recharge. A warranty compressor ordered through a distributor can add a few days to the wait, and a burnout clean-up adds a return visit to re-test the oil.