In North Texas a heat pump works as your air conditioner for more of the year than it works as your heater, and most of our winter hours fall right where heat pumps do their best work. A good install comes down to a few decisions that are easy to skip: sizing for summer, picking how much backup heat to put in, deciding whether to keep a gas furnace, and checking that your electrical panel can carry the load. For the basic comparison of the two systems, start with our heat pump vs. furnace guide.
Why heat pumps suit a North Texas house
Heating loads for the Dallas area are calculated for an outdoor design temperature in the 20s°F, a level the area drops below for only about 1% of the hours in a typical year. Most heating here happens on days in the 30s, 40s and 50s, where even a basic heat pump delivers two to three units of heat for every unit of electricity it uses.
The exception is the rare deep freeze. During Winter Storm Uri, DFW Airport hit −2°F on February 16, 2021, its coldest reading since 1949. A heat pump still runs at temperatures like that, but at a fraction of its rated output, so the backup heat you choose decides how the house holds up.
Size it for summer, then plan for winter
It's tempting to buy a heat pump big enough to heat the whole house on the coldest night. Here, that trade goes badly. A heat pump sized for January is oversized for July. It cools in short bursts and shuts off before it has pulled much moisture out of the air, so rooms end up cool but clammy all summer, the season when the system works hardest.
So we size the heat pump to your summer cooling load, from a room-by-room load calculation (the same Manual J process described on our AC installation page), and let backup heat cover the winter shortfall. Variable-speed models are more forgiving, because they slow down in mild weather instead of cycling on and off.
Single-stage, two-stage, variable-speed and cold-climate models
- Single-stage runs at full output or not at all. At 17°F, a typical single-stage heat pump makes somewhere around half to two-thirds of the heat it makes at 47°F, so it leans on backup heat sooner.
- Two-stage adds a low speed for mild weather and saves full capacity for hot afternoons and cold mornings. Better humidity removal, fewer strip hours.
- Variable-speed (inverter) compressors adjust output in small steps. In winter they speed up to hold more capacity as it gets colder; in summer they run long and slow, which is the best humidity control a heat pump offers.
- Cold-climate models carry an ENERGY STAR designation that requires them to keep at least 70% of their 47°F heating capacity at 5°F. North Texas doesn't require one, but in an all-electric home it shrinks the backup heat you need for a storm like Uri.
Every new split heat pump must meet at least 14.3 SEER2 for cooling and 7.5 HSPF2 for heating (HSPF2 numbers run lower than the old HSPF scale for the same equipment). A heat pump here cools for more of the year than it heats, so look at SEER2 first. In an all-electric home, give HSPF2 more weight. New systems use the newer A2L refrigerants, R-454B or R-32, rather than R-410A.
Balance point: how much backup heat to install
Every heat pump has a balance point: the outdoor temperature at which its output exactly matches your home's heat loss. Above it, the heat pump carries the house alone. Below it, backup heat makes up the difference. Each kilowatt of heat strip adds about 3,412 Btu per hour.
Here's a simplified example with round, illustrative numbers. Say a home loses 40,000 Btu/h when it's 25°F outside, and its 3-ton single-stage heat pump makes about 24,000 Btu/h at that temperature. The strips need to cover 16,000 Btu/h, about 4.7 kW, so a 5 kW kit just covers it and an 8 or 10 kW kit leaves margin. But if the outdoor unit fails on that same night, emergency heat has to carry all 40,000 Btu/h by itself: about 11.7 kW. And at −2°F, the same house would lose roughly 64,000 Btu/h while the heat pump makes far less, so the gap approaches 15 kW. Your real figures come from your load calculation and the manufacturer's performance tables.
So strip size is a trade. A bigger kit needs a bigger breaker and heavier wire, and in return it can carry the house if the outdoor unit quits in January. Go smaller and you save on wiring but come up short on that night. We show you the numbers and you choose. We also set outdoor-temperature lockouts at the thermostat, so the strips can't run on mild mornings when the heat pump doesn't need help.
Dual fuel: a heat pump paired with a gas furnace
If your home has natural gas, a gas furnace can serve as the backup instead of strips. The heat pump handles cooling and mild-weather heating, and below a switchover temperature the furnace takes over.
- The heat pump's indoor coil sits on the furnace's supply side, and the controls never run both in normal heating. Hot furnace air across a working heat pump coil drives refrigerant pressure up until a safety switch shuts the compressor down. The one exception is defrost, when the furnace may fire briefly so you don't feel cool air.
- The switchover point is adjustable. It depends on your electric and gas rates and on how warm you like the air, so we set it with you instead of leaving the factory default.
- If your furnace is fairly young and in good shape, you can often keep it and replace only the AC with a heat pump, as long as the furnace blower can be matched to the new coil. Our furnace installation page covers the furnace side of that decision.
- Propane works the same way, but it usually costs more per unit of heat than natural gas, so the switchover is typically set lower and the heat pump does more of the work.
Converting from an AC and gas furnace to all-electric
Dropping gas heat entirely is doable, but more changes than the equipment:
- The furnace is replaced by an air handler with heat strips, which needs a new 240-volt circuit the furnace never had.
- The gas line to the furnace has to be properly capped. If gas still serves a water heater, range or fireplace, the meter and the rest of the piping stay.
- Watch the water heater vent. In many homes the gas water heater shares a flue with the furnace. Take the furnace off that flue and the vent can be too large for the water heater alone, which can make it draft poorly and spill combustion gases, including carbon monoxide, into the house. The vent has to be checked and resized as part of the job.
- Attic ducts matter more. Heat pump air is cooler than furnace air, so leaky or poorly insulated attic ductwork costs you more comfort in winter. If yours are in rough shape, see our ductwork page.
Homes without natural gas
Plenty of homes around Terrell were built all-electric, especially rural properties beyond the gas lines and many manufactured homes. If yours heats with an electric furnace today, a heat pump is the biggest efficiency upgrade available to you: in mild weather it delivers the same heat for roughly a third to half the electricity, and heat strips stay in the air handler as backup. You can see what those strips cost to run on our electric furnace and heat strip page.
In an all-electric home, the backup-heat decision above carries more weight, because there's no gas furnace to fall back on. That's where two-stage, variable-speed and cold-climate models earn their extra cost.
Your electrical panel and breakers
A heat pump system usually needs two 240-volt circuits: one for the outdoor unit, sized from its nameplate, and one or two for the air handler and its strips. Strips draw serious current, about 21 amps for every 5 kW at 240 volts. A 10 kW kit typically needs a circuit of around 60 amps, and 15 and 20 kW kits are often split across two circuits.
Before we quote, we look at your panel. Many older homes have 100-amp panels already carrying an electric range, dryer and water heater. If yours can't take the new circuits, the options are a smaller strip kit, dual fuel, or a panel upgrade by a licensed electrician. We'd rather you hear that in the quote than on install day. Panel capacity matters most when converting from gas, since the furnace you're removing drew only a few amps.
You get a written quote before any work is scheduled, and every installation carries our 1-year labor and 10-year parts warranty.
Financing is available on new heat pump systems. Ask about it when we prepare your quote, or start with a ballpark price on our online estimate page.