We test before we replace anything. When your system quits in the middle of a Terrell summer, our technicians keep measuring until the cause is certain, show you what they found and give you a written price before any work begins. Most summer breakdowns come down to one of a handful of electrical parts we keep on the truck, so a lot of repairs are finished on the same visit.
What a proper AC diagnosis looks like
Swapping parts until the system starts gets expensive fast, because you pay for every part that wasn't the problem. This is the order we work in, and what each step tells us:
- Your account first. When did it start? Does it fail every afternoon, or did it stop all at once? Did a storm roll through? The pattern narrows the list before we open a panel.
- Power and controls. We confirm the breakers, the outdoor disconnect and the 24-volt signal from the thermostat. Plenty of "dead" systems turn out to be a tripped float switch or a blown control fuse.
- Electrical components. We measure each capacitor against its rated microfarads, check the contactor for burned or pitted contacts, and read the amp draw of the compressor and both fan motors against their nameplate ratings.
- Performance. With the system running, we measure the temperature drop across the indoor coil. A healthy system usually cools the air roughly 15–20°F. Then we read refrigerant pressures, superheat and subcooling to see whether the charge is right.
- Airflow. Filter, coil, ducts. A clogged filter, matted coil or crushed duct can look like a low charge on the gauges, so we rule them out before anyone touches the refrigerant.
At the end we tell you what failed and why, and put the price to fix it in writing. Nothing gets replaced until you approve it.
Symptoms and what usually causes them
We see these over and over on summer service calls. They tell us where to start looking, and the meters take it from there:
| What you notice | Common causes |
|---|---|
| Outdoor unit hums, but the fan doesn't spin | Failed run capacitor or a seized fan motor |
| Indoor blower runs, outdoor unit is silent | Contactor not engaging, tripped breaker, low-voltage wiring fault |
| Nothing runs and the thermostat is blank | Tripped float switch, blown control-board fuse, failed transformer |
| Air moves, but it isn't cold | Outdoor unit not running, low refrigerant, very dirty outdoor coil |
| Weak airflow from every vent | Clogged filter, iced or dirty indoor coil, failing blower motor |
| Runs a few minutes, shuts off, starts again | Overheating compressor, low charge, oversized system, thermostat issues |
| Breaker trips when the AC starts | Shorted motor or compressor winding, failed hard-start part, damaged wiring |
If there's ice on the copper lines or the indoor coil, turn the system off so it can thaw before we get there. Our article on why an AC freezes up explains what usually causes it.
The parts that fail most in North Texas heat
Capacitors
A capacitor gives the compressor and fan motors the kick they need to start. It's small and cheap, and it sits in a metal cabinet in full sun, where the heat wears it down a little more every summer. We test it in microfarads against the rating printed on its side. One that reads well below that number will often still start the system in the cool of the morning and then fail on a hot afternoon. Left alone, it makes the compressor strain on every start.
Contactors
The contactor is the switch that sends full power to the outdoor unit when the thermostat calls for cooling. Every cycle makes a small spark across its contacts, and after enough summers they pit and burn. Texas fire ants make it worse. They're drawn to electrical contacts and can pack into a contactor until it won't close, or jam it so it won't open.
Fan and blower motors
When the outdoor fan stops, the compressor quickly overheats and shuts itself off on its internal overload. To someone in a hurry, that looks like a much bigger failure than it is. Indoors, a lot of newer systems use variable-speed blower motors, and the electronic module on those doesn't handle power surges well.
Control boards and low-voltage wiring
Thin thermostat wire runs through the attic and out to the condenser, where it can be chewed, rubbed through or cut by a string trimmer. A short in that wire blows the small fuse on the furnace or air handler control board, and the whole system goes quiet. We trace the short before we touch the fuse. If nobody finds it, the new fuse blows just like the old one.
Bigger components have their own pages. If someone has told you the compressor is gone, start with AC compressor repair. For a leaking indoor coil, see evaporator coil replacement.
Checks you can safely do before you call
- Make sure the thermostat is set to Cool and below room temperature, and replace its batteries if it uses them.
- Reset a tripped breaker for the indoor or outdoor unit once. If it trips again, leave it off.
- Pull the air filter. If you can't see light through it, replace it.
- Look at the drain pan under an attic or closet unit. Standing water usually means the drain is clogged and the float switch has shut the system off to protect your ceiling.
- Clear grass clippings, leaves or anything stacked against the outdoor unit.
Leave the electrical panel on the outdoor unit closed. A capacitor can hold a dangerous charge even with the power off, so anything behind that panel is a job for a technician.
How repair pricing works
The diagnostic visit is free. Once we know what's wrong, you get a written price for the repair before any work starts, so the number you approve is the number on the invoice. Repairs are backed by our 30-day repair warranty.
For a big repair on an older system, like a compressor or coil on equipment in its teens or anything major on an R-22 unit, we'll price a replacement alongside it so you can compare the two. Our AC installation and replacement page covers how to weigh that. If another company has already quoted you a big repair, we're glad to give you a second opinion.