By Census Bureau estimates, the median Oak Grove home was built in 1978, more than nine in ten households heat with electricity, and almost every home in town is a detached single-family house. The town incorporated in the 1970s and, unlike most of Kaufman County, hasn't boomed since: 557 residents in 1990, 617 in 2020. It's long and narrow, about half a mile wide and three miles long according to the Handbook of Texas, and lies along FM 1388 just south of Kaufman.
What a late-1970s all-electric house started with
Homes from this era built without natural gas were commonly fitted with an electric furnace, a blower cabinet with resistance heating elements, paired with a central air conditioner. Some got early heat pumps instead. The original equipment has long since been replaced, often more than once, but the layout it set up usually remains: where the air handler sits, how the ducts run, and often a single large central return.
Each replacement tends to copy the last one, because a like-for-like swap is the quickest job. So if the house started with resistance heat, there's a good chance it still has it, and that one detail drives most winter electric bills in town.
When to move from resistance heat to a heat pump
The right moment is usually when the outdoor unit needs replacing anyway. A heat pump is an air conditioner that also heats, so choosing one instead of another straight AC adds some cost to a purchase you were already making, while resistance heat becomes the backup instead of the main source. Switching earlier, while a working AC still has years left, is harder to justify.
Until then, keep the electric furnace you have in good shape. Uneven heat, a breaker that trips on cold mornings or a burning smell that lingers past the first run of the season are electric furnace and heat strip repair problems. Our heat pump vs. furnace guide covers the running-cost basics.
Ducts and insulation older than the equipment
In a house built around 1978, the ductwork may be original and more than 45 years old. Duct board and flex duct from that era split at the seams, sag, and lose insulation value, and every leak in an attic run dumps cooled air into a space that can pass 130°F in summer. Hook a new high-efficiency system to ducts like that and it won't come close to its rating.
Attic insulation in homes of this age is often thinner than today's recommendations, and it may have settled or been disturbed over the years. The U.S. Department of Energy's insulation guide lists recommended levels by region. Adding insulation lowers the load a new system has to meet, sometimes enough to justify a smaller one.
An upgrade order that makes sense
If you're planning to bring an older Oak Grove house up to date, this sequence avoids paying twice:
- Fix anything unsafe or failing first, like scorched heat strip wiring, a tripping breaker, or a system that can't keep up.
- Seal and repair the ducts and add attic insulation, since both change how much heating and cooling the house needs. Our ductwork page explains how leakage is tested and sealed.
- Size the new system with a load calculation on the improved house. The old unit's label only tells you what the last installer picked. Our AC installation page explains why.
- Choose between a heat pump and an air conditioner with an electric furnace, with the running-cost difference in front of you.
- Set the thermostat up for the equipment you chose, so a heat pump doesn't call for strip heat every time you adjust it.
What has changed in new equipment
If your current system dates from before about 2010, expect a few changes when it's replaced. Older units commonly run on R-22, which hasn't been produced or imported since 2020. New split air conditioners and heat pumps use A2L refrigerants such as R-454B or R-32, and efficiency is now rated in SEER2. In Texas, a new split air conditioner under 45,000 Btu/h (about 3.75 tons) must reach at least 14.3 SEER2, or 13.8 SEER2 at larger sizes, and a split heat pump needs 14.3 SEER2 and 7.5 HSPF2. A new outdoor unit also needs a matched indoor coil, so the indoor side gets replaced too. Get the ducts and insulation done before that happens.