Serving Terrell, TX & Nearby Towns

Hangar One technician checking an outdoor AC unit's refrigerant lines with an electronic leak detector in Terrell, TX

Refrigerant Leak Detection & Repair in Terrell, TX

Refrigerant doesn't get used up. If yours is low, there's a leak, and we track it down before anyone adds a pound.

Technician running an electronic leak detector along an indoor AC coil to find a refrigerant leak in Terrell, TX

Your air conditioner doesn't burn refrigerant or wear it out. It circulates through a sealed loop, and the charge that went in on installation day should still be there the day the system is retired. If a technician tells you the system is low, they've found a hole. What you need to know next is where it is, how fast it's leaking, and whether it's worth fixing.

Why a refrigerant top-off turns into a recurring bill

Adding refrigerant to a leaking system brings the pressure back for a while. A fast leak can lose that charge again in a few weeks, a slow one over a season. Then you pay for the visit and the refrigerant again.

Running short between top-offs costs you too. Run times get longer, the bill goes up, and the indoor coil can freeze (see why an AC freezes up). The compressor takes the worst of it. Most residential compressors are cooled by the refrigerant vapor coming back to them, so a starved system runs them hot, and that's one of the more common roads to an early compressor failure.

The EPA gives homeowners the same advice: ask technicians to locate and repair leaks instead of “topping off”. There's one exception. If the system is old and you've already decided to replace it before next summer, a recharge to get through the season can be reasonable, as long as you know the leak is still there.

Signs your system is running short

Any one of these can also come from a clogged filter or a dirty coil. Two or three together are worth a call.

It can't keep up on hot afternoons

Capacity falls as the charge falls. A slightly low system may hold its setting in the morning and drift several degrees by late afternoon. A little worse every summer usually means a slow leak.

Frost on the larger copper line or the indoor coil

Low charge drops the pressure, and with it the temperature, inside the indoor coil until the moisture on it freezes. Frost where the larger, insulated line meets the outdoor unit is a common giveaway. Turn cooling off and let it thaw before calling.

An oily, dusty patch on a fitting

Refrigerant carries a little compressor oil with it, so leaks tend to leave an oily film that collects dirt. You can check for this without opening any panels. Look at the copper valves where the lines enter the outdoor unit, and point out any dark, greasy smudge to us when we arrive.

A heat pump that struggles in winter

A heat pump heats with the same refrigerant charge it cools with. When it leaks, the system leans harder on its backup electric heat, and the first sign is often a high winter bill. Our heat pump repair page covers the other causes.

What a refrigerant leak search involves

First we make sure the system really is low. We check airflow, since a dirty filter or coil can make a correctly charged system read low, then compare measured superheat or subcooling with the manufacturer's target. No single tool finds every leak, so we use several.

Electronic leak detector

A handheld sensor that alarms near refrigerant. It's the fastest way to narrow a search to one area, but cleaners and adhesives can set some sensors off, and a coil sealed inside its cabinet is hard to reach without removing a panel.

Bubble solution

Brushed onto a suspect joint or valve, it foams where gas escapes. It's simple and leaves no doubt about the exact spot, so it's the usual way to confirm what the detector found. It won't show the slowest leaks.

UV dye

Fluorescent dye goes into the system and travels with the oil. Days or weeks later, a UV lamp makes the leak glow. Dye is good at catching leaks that only open when the system is hot and vibrating. It needs run time, though, which means a return visit, and it has to suit the system's oil and the equipment maker's requirements.

Nitrogen standing-pressure test

The refrigerant is recovered, and the system is filled with dry nitrogen, kept within the pressure limits printed on the equipment, and left on a gauge. A falling pressure confirms a leak. Because the indoor coil, line set and outdoor unit can be tested separately, this is also how we prove which section is leaking when the hole itself can't be seen, like on an attic coil sealed inside its cabinet.

Why some leaks take more than one visit

A leak that loses a few ounces over a summer may not register on a detector on a given day, and some only open when the metal expands in afternoon heat. Dye and pressure tests both need time. When a search needs extra time, a return trip or parts, you get a written price for that first.

Oily, dust-caked residue on a copper AC fitting, the classic sign of a refrigerant leak, at a Terrell, TX home

Where leaks usually turn up

  • The indoor evaporator coil. One of the most common leak points, usually from corrosion. Our evaporator coil replacement page explains why coils fail and how a new one is matched to your system.
  • Service-port valve cores. The small Schrader valves technicians connect gauges to can seep, especially when their caps are missing. It's one of the cheapest leaks to fix.
  • Rub-outs inside the outdoor unit. Small copper tubes that vibrate against each other or the cabinet for years can wear clean through.
  • Flare fittings on mini-splits. Ductless systems connect with threaded flare nuts instead of brazed joints, and a flare that was cut or tightened incorrectly is the usual leak point.
  • The line set. String trimmers nick the copper where it meets the house, screws and nails find it inside walls during remodels, and outdoor pads settling on the area's expansive clay soil can strain the connections at the unit.
  • Brazed joints and service valves on older equipment, after years of heating and cooling cycles.

R-22, R-410A and the newer A2L refrigerants

Which refrigerant your system uses changes the economics of a leak more than anything else. It's printed on the outdoor unit's nameplate.

R-22: most systems installed before 2010

Production and import of R-22 ended on January 1, 2020. What's left is reclaimed or stockpiled, and it's priced that way. The EPA notes there are no true drop-in substitutes: alternatives won't work well without changes to the system. On an R-22 system with more than a minor leak, replacement usually wins.

R-410A: most systems from about 2010 to 2025

R-410A is still produced for servicing existing equipment, and the EPA confirms these systems can keep being repaired, including replacing a condensing unit or compressor. As an HFC, though, its production is being stepped down under federal law, and the EPA cautions that availability may lessen over time. A leak you keep topping off will only get harder to feed.

R-454B and R-32: newer systems

New systems now generally use A2L refrigerants, which are classed as lower toxicity and mildly flammable. Most ducted A2L systems carry a refrigerant sensor in the indoor unit that runs the blower to disperse refrigerant if it detects a leak. Leaks are found and fixed the same way, with recovery equipment and procedures rated for A2Ls.

A system stays on the refrigerant it was built for, and different types are never mixed. Anyone recovering or adding refrigerant must hold EPA Section 608 certification. Venting it into the air is illegal.

Fix the leak, replace a part, or replace the system

Where the leak is decides most of this.

Where the leak isUsual fixWhen replacement makes more sense
Valve core or missing capNew core and a sealing capAlmost never, on its own
Rub-out or joint that can be reachedBraze it, then clamp or reroute the tubing so it can't rub againWhen it's one of several leaks on an aging unit
Mini-split flare fittingCut and re-make the flare, tightened to specRarely
Line set inside a wall or slabAbandon it and run a new line setWhen the system is near the end of its life anyway
Indoor coilReplace the coilOn R-22 systems, or when the outdoor unit is aging too
Outdoor coilReplace the coil or the condensing unitOn most older systems

After location, it comes down to the refrigerant, how many leaks turn up, and the age of everything else. If you'd be replacing the system within a couple of years anyway, putting the repair money toward a new, properly sized system can be the better buy. We'll write up prices for both so you can compare them side by side.

However the leak gets fixed, we prove the repair before we call it done. That means a nitrogen pressure test, a deep vacuum to pull out air and moisture, the correct weight of refrigerant, and a final check of superheat or subcooling against the manufacturer's targets.

Questions About Refrigerant Leak Repair

My AC was recharged last summer and it's low again. Did the technician do something wrong?

Not necessarily. But the leak was never fixed. Refrigerant doesn't get used up, so a system that needs more every year has a hole somewhere, and each recharge just restarts the clock. What you need now is a leak search and a written price to fix what it finds. Hang on to the old invoices. How much was added, and when, tells us roughly how fast it's leaking.

How long does it take to find a refrigerant leak?

An obvious leak, like a seeping valve core or an oily rub-out, can be found and confirmed in one visit. Slow leaks take longer. A nitrogen standing-pressure test needs time on the gauge, and UV dye needs days or weeks of run time before it glows. If your leak needs a second visit, you'll know why and what it costs, in writing, before any more work is done.

Can I add refrigerant to my home AC myself?

Not really. Under EPA rules, refrigerant for home air conditioners can only be sold to technicians with Section 608 certification. The small DIY cans at the auto-parts store are for cars. Charging a home system also takes gauges, line temperatures and the manufacturer's targets, and an overcharge can damage a compressor just as surely as running it short.

Is it worth repairing a leak on an older R-22 system?

Sometimes. If the leak is a valve core or a joint that's easy to reach and the rest of the system is healthy, a repair plus reclaimed R-22 can buy a few more summers. If it's in the indoor or outdoor coil, the numbers usually go the other way. The part, the labor and a full charge of a refrigerant that's no longer produced add up to a real share of a new system on a current refrigerant.

Can't you just inject a leak sealant instead?

Sealant additives are sold for exactly that. They're a gamble. They harden where they meet air or moisture, and that can happen inside a metering device or filter-drier instead of at the leak. They can also contaminate the recovery equipment used on the system later. If a sealant was ever added to your system, tell us before any work starts.

My new system uses R-454B. Is a refrigerant leak dangerous?

R-454B and R-32 are classified as A2L refrigerants: lower toxicity and only mildly flammable, which makes them much harder to ignite than propane-type refrigerants. Most ducted A2L systems also include a sensor that runs the blower to disperse refrigerant if it detects a leak. If your system shows a refrigerant-sensor alert, don't try to reset or bypass it. Book a service visit instead.

Low on Refrigerant? Find the Leak

Book online in minutes or call (972) 555-0100. The diagnostic is free, and you get a written price before any work begins.

Book Online