If you grew up with a gas furnace, a working heat pump can look broken. It throws steam off the outdoor unit, runs for hours on a cold afternoon, and the air at the vents feels barely warm on your hand. Most of that is by design. Below, we sort the normal from the real faults and cover the parts only a heat pump has: the reversing valve, the defrost controls, and the backup heat that can run up a winter bill without anyone noticing.
How a heat pump pulls heat out of cold air
In heating mode, your heat pump runs its air-conditioning cycle backwards. Refrigerant in the outdoor coil is colder than the outdoor air, so even 30°F air gives up heat to it. The compressor raises that heat to a useful temperature, and the indoor coil releases it into your ductwork. The reversing valve flips that flow between summer and winter.
The colder it gets outside, the less heat a heat pump can move, and that's exactly when your house loses heat fastest. Below a certain point, electric heat strips in the indoor unit fill the gap.
Normal or a problem? A quick guide
| What you notice | Usually normal when… | Call us when… |
|---|---|---|
| Steam rising from the outdoor unit, fan stopped | It lasts a few minutes and recurs every 30–90 minutes of run time on cold, damp days. | Ice remains after the steam stops, or the unit never seems to defrost. |
| A loud whoosh from outside | It comes as defrost starts and ends, or as the system shuts off. | The hiss is continuous, or you hear grinding, banging or squealing. |
| Air from the vents feels lukewarm | It's often in the 90s°F, near skin temperature, so moving air feels cool on your hand. Furnace air is often 120°F or more. | The air is room temperature or colder while the thermostat is on Heat. |
| The system runs for hours | It's in the 30s or colder outside and the house still holds your setting. | It can't keep up on a 45°F day, or it never shuts off in mild weather. |
| “Aux” shows on the thermostat | It's a cold morning, the unit is defrosting, or you just raised the setting several degrees. | Aux is on most of the day when it's 40°F or warmer outside. |
| Frost on the outdoor coil | It's a thin, even white layer that clears on the next defrost. | Ice is thick and clear, covers the top or fan, or keeps building from the base. |
Defrost is the one that worries people most. When frost builds on the outdoor coil, the control board briefly switches the system into cooling mode to warm the coil. It stops the outdoor fan so that heat stays in the coil, and usually turns on the heat strips so you don't feel cold air indoors. The steam is meltwater coming off a warm coil. It isn't smoke, and it isn't a refrigerant leak.
When the outdoor unit ices over and stays that way
A heat pump that can't clear its ice loses most of its capacity and hands the work to the strips. Besides the fan and refrigerant problems covered below, the usual reasons are:
- The defrost board. Many boards check for frost every 30, 60 or 90 minutes of run time, and one that never starts a defrost lets ice grow into a solid block. On boards with an adjustable interval, 90 minutes can let too much frost build in damp, near-freezing weather. Moving it to a shorter setting is an easy fix.
- Defrost sensors. A sensor clipped to the outdoor coil (plus an air sensor on demand-defrost systems) tells the board what's happening. If it fails or slips off its tube, the board gets bad readings.
- Water with nowhere to go. Defrost sheds water out the bottom of the unit. If the pad has settled or tilted in our Blackland Prairie clay, the base pan can sit in its own meltwater and refreeze overnight. A gutter dripping onto the cabinet does the same from the top.
Freezing rain is a separate case, since an ice storm can encase the cabinet faster than defrost can melt it; see our emergency heating repair page for that. Whatever the cause, don't chip at ice on the coil. The fins and tubing puncture easily.
The reversing valve, and the noises that matter
The reversing valve is a brass valve in the outdoor unit with an electric solenoid coil mounted on it. The solenoid shifts a slide inside the valve, sending hot refrigerant either indoors for heat or outdoors for cooling and defrost. The whoosh when it shifts is harmless. When it goes wrong, it's one of three things:
- The solenoid coil burns out. The easy one. It's an electrical part, and we can replace it without opening the refrigerant circuit.
- The slide sticks. The system heats or cools in both modes, depending on where it's stuck.
- The slide leaks internally. Hot gas slips straight back to the compressor, so you get weak heating and cooling, a steady hiss and higher bills.
Before blaming the valve, rule out one look-alike. A new thermostat with the wrong O/B setting will cool when you ask for heat, so if the trouble started right after a thermostat swap, see our thermostat installation and setup page. Otherwise we check voltage at the solenoid and compare temperatures on the lines in and out of the valve. If the valve body has to come out, that means recovering the refrigerant, brazing in the new valve under a nitrogen purge, then evacuating and recharging.
Outdoor fan and refrigerant problems in heating mode
In winter the outdoor fan pulls air across the coil so the refrigerant can collect heat from it. Outside of defrost, it should run whenever the compressor does. If the fan motor or its capacitor fails, or a blade is frozen in place, the coil gets very cold very quickly, ices over and can trip the compressor off on its low-pressure safety.
Low refrigerant looks similar: weak heat, fast frosting, more aux heat. A low charge means a leak somewhere, and the reversing valve's extra brazed joints are one more place to check. Our refrigerant leak repair page explains how we find them. Cold weather makes the charge hard to read accurately, because the standard charging checks are written for cooling mode. In winter we often recover the refrigerant and weigh the factory-specified amount back in. On an R-22 heat pump, a major leak is usually the end of the system; new R-22 hasn't been produced since 2020.
Aux heat vs. emergency heat
Aux heat is automatic. The thermostat brings in the strips during defrost, when the heat pump alone can't hold the temperature, or when you bump the setting up several degrees at once. “Aux” on a cold morning is fine.
Emergency heat is manual. It shuts the heat pump off and heats the house with strips alone. Use it only when the outdoor unit can't run: it's iced solid and not clearing, damaged by hail or a fallen limb, or we've asked you to use it until a repair is made. Cold weather alone is no reason to switch. Even at 20°F, a working heat pump usually makes more heat per kilowatt-hour than strips do. On a dual-fuel system, emergency heat runs the gas furnace instead, so the cost penalty is much smaller.
Why your winter electric bill jumped
In mild weather, heat strips use roughly two to three times as much electricity as the heat pump for the same heat. A winter bill spike usually means the strips are running too much (our heat strip and electric furnace page shows what they cost per hour). The usual reasons:
- The outdoor unit isn't running at all. The strips carry the whole house, it stays warm, and nobody notices until the bill arrives. With the heat on, step outside and look. Unless it's defrosting, the fan should be turning and the unit humming.
- Emergency heat left on after a cold snap.
- Large setbacks. Dropping the thermostat 6–8°F overnight turns every morning warm-up into a strip-heat event.
- Aux settings that are too eager. A tight staging setting or a missing outdoor-temperature lockout lets the strips run on 45°F mornings.
- An underperforming heat pump, from low charge, a leaking reversing valve, an iced coil or a clogged filter, so the thermostat keeps calling for help.
What we check on a heat pump call
We run the system in both modes, force a defrost to watch the board, valve and fan respond, measure the temperature rise across the indoor coil, and check amp draw on the compressor, the outdoor fan and each stage of heat strips. You get the cause and a written price before any work starts. The diagnostic visit is free, and repairs carry our 30-day repair warranty.
Most heat pumps last roughly 10–15 years. If yours is near the end of that range and needs a reversing valve or compressor, we'll tell you plainly how the repair stacks up against a new heat pump. The defrost test in a fall heating tune-up catches a lot of these problems before the first freeze.