The evaporator coil is the indoor half of your air conditioner. It sits on top of the furnace or inside the air handler, in the attic or a hall closet, and it's where heat and humidity leave the house. Most homeowners never see it, because it's sealed in a sheet-metal box. When it fails, it's usually a pinhole leak, and what you notice is a charge that's a little lower every summer and a system that runs longer to keep up.
What the indoor coil does
Refrigerant enters the coil as a cold liquid and boils inside the tubes at roughly 40°F, soaking up heat from the air the blower pushes across the fins. In a healthy system, air leaving the coil is about 15–20°F cooler than air going in. That difference, the temperature split, is one of the first numbers we check. The coil also does most of your dehumidifying. Water vapor condenses on the cold fins and drips into a drain pan, and on a muggy day that's a lot of water.
In a closet it's usually an A-shaped coil on top of an upright furnace. In an attic it's often a horizontal coil beside a furnace lying on its side, or a coil built into an air handler. Either way it's boxed in. A badly corroded coil looks fine from the outside.
Why indoor coils leak
Formicary corrosion
The best-known cause of copper coil leaks is formicary corrosion, named for the ant-nest pattern of microscopic tunnels it eats through the tube wall. It needs four things at once: copper, moisture, air, and organic acids such as formic and acetic acid. Those acids come from volatile organic compounds (VOCs) given off by adhesives, particleboard, paint, cleaning products, air fresheners, cosmetics, even vinegar. By the time the tunnels reach the surface, there's rarely just one.
North Texas supplies the moisture, since an indoor coil here stays wet through a long, humid cooling season. Tighter, newer homes tend to hold onto more VOCs. When everything lines up, leaks can show up within months. Store paint, solvents and cleaners somewhere other than the furnace closet; for ventilation options, see our indoor air quality page.
Corrosion where copper meets aluminum
Traditional coils pair copper tubes with aluminum fins, and constant moisture lets the two metals react where they touch. Many manufacturers moved to all-aluminum coils partly for that reason, and with no copper in the tubes, formicary corrosion has nothing to attack. They're harder to fix, though. Aluminum tubing melts below standard brazing temperatures, so a field repair takes special materials and often isn't practical.
Vibration, rub-outs and physical damage
The small distributor tubes that feed each circuit can rub against each other or the cabinet over the years, and the U-bends at the coil ends take the most stress. Sometimes it's a screw driven through the coil during an earlier repair. How we pin down the leak, including a nitrogen test that isolates the coil, is on our refrigerant leak repair page.
Cleaning, repairing or replacing the coil
When cleaning is the answer
A dirty coil that isn't leaking just needs cleaning. Dust and pet hair mat onto the intake side when the filter is missing, the wrong size, or leaves a gap in the rack. You get weak airflow, long run times and, eventually, a frozen coil. Cleaning brings the airflow back. It won't fix a leak, and a cased coil sometimes has to be partly pulled out to clean it properly. The best prevention is a filter that fits the rack and gets changed on schedule.
When a leak can be repaired in place
A single leak at an accessible U-bend or distributor tube on a copper coil can sometimes be brazed, especially when the rest of the coil is clean and sound. Formicary leaks are poor candidates. Once one pinhole breaks through, others are usually close behind, and a patched formicary coil tends to leak again somewhere else.
When replacement is the fix
Replace the coil when it has more than one leak, a leak buried in the middle of the coil where it can't be reached, widespread corrosion, or fins that have crumbled or collapsed.
Matching a new coil to the outdoor unit
The replacement coil has to match the outdoor unit on five points, or the system may never cool or dehumidify the way it's rated to.
- Refrigerant. The coil must be listed for the refrigerant in your outdoor unit. R-410A runs at much higher pressures than R-22, and coils for A2L refrigerants (R-454B or R-32) include a refrigerant leak sensor. Some current coils are listed for both R-410A and R-454B.
- Capacity. Matched to the outdoor unit's tonnage, even when a bigger coil would fit the space.
- Metering device. Either a fixed piston sized for the outdoor unit or an expansion valve (TXV). Many higher-efficiency outdoor units call for a TXV. If the coil uses a piston, we swap it for the size the outdoor unit's instructions specify.
- Certified combination. A system's SEER2 rating applies only to specific indoor and outdoor combinations tested and listed with AHRI, and some manufacturers' warranties expect a listed match.
- Fit and airflow. The cabinet has to line up with the furnace or air handler, suit the airflow direction (upflow, downflow or horizontal), fit the space, and work with a blower set to the right airflow for the coil.
A coil from the outdoor unit's manufacturer is the simplest route. Other brands work when the combination is listed. A poor match shows up as a house that never feels quite dry, a coil that ices over, or liquid refrigerant flooding back to the compressor.
What an attic coil replacement involves
A lot of North Texas homes have the coil in the attic, and that changes the job. The core work is the same anywhere: recover the refrigerant, pull the old coil, adapt the plenum if needed, braze in the new coil under a nitrogen purge, then pressure-test, evacuate and charge. The attic adds two things.
Getting to the equipment
Current residential codes call for a floored walkway from the attic opening to the equipment, a level work platform in front of it, and a light and outlet nearby. Plenty of older installs have none of that. The new coil still has to fit through the opening and along that path, in an attic that can pass 130°F in summer, so if the path isn't safe, fixing it becomes part of the job.
The secondary pan and float switch
An overflowing attic coil drains straight into a ceiling, so codes require a backup. That's either a secondary pan under the unit with its own drain line ending somewhere you'll notice it (often above a window), or a float switch that shuts the system off before water overflows. If water is dripping from that pipe, the main drain is clogged. Older metal pans rust through. Float switches go missing, or get wired so they can't do their job. With the coil already coming out, that's the time to replace a rusted pan and test the switch. Routine drain care is part of AC maintenance.
What the coil warranty pays for
Indoor coils often fail while the manufacturer's parts warranty still applies. For the major brands that's typically 10 years on registered equipment, and less if it was never registered. The warranty supplies the replacement coil. The attic labor, the refrigerant, and the materials around the coil (filter-drier, brazing alloy, a new transition or secondary pan) generally aren't covered.
Have the model and serial numbers and the installation date handy. On a system that's only a few years old, dig out the installer's paperwork too. Their labor warranty may still apply.
When a failed coil is the moment to replace the system
A new coil on an otherwise healthy system is a sound repair. Price a whole new system instead when:
- The system runs on R-22. A new coil plus a full charge of reclaimed R-22 is a lot to spend on equipment of that age.
- The outdoor unit is past about 12 years. Replace the coil now and the condenser in two years, and you pay for the labor, refrigerant and attic work twice, for a system whose halves are different ages.
- No listed match exists. Coils for some older outdoor units aren't made anymore.
- The furnace or air handler is aging too. The plenum and transition work is being done either way, so replacing everything at once avoids doing it again.
- Comfort was never right. Hot rooms or sticky air that predate the leak point to sizing or ductwork problems a new coil won't fix.
The refrigerant change plays into this too. Putting a new R-410A-compatible coil on an R-410A system is still a permitted repair, and those coils are still made. A complete new system will generally use an A2L refrigerant like R-454B or R-32. Our AC installation page explains what that means for you.