Electric resistance heat is about as simple as heating gets. Current runs through a coil of nickel-chrome wire, the wire glows red hot, and a blower pushes air across it. There's no flame and no refrigerant to worry about. Those few parts do carry heavy current at 240 volts, though, from about 20 amps for a single 5 kW element to more than 80 for a 20 kW furnace. When one fails, you usually find out from lukewarm air, a burning smell or a tripped breaker. This page covers how electric heat works, what breaks, what it costs to run, and what you can safely check yourself.
Where electric heat shows up in your home
- Electric furnace. An air handler whose elements are the main heat source, usually paired with a separate outdoor air conditioner. Common in homes built without gas service.
- Heat strips in a heat pump air handler. The same elements, used as backup when the heat pump can't keep up and during defrost. If they're running more than they should, the cause is usually on the heat pump side; see heat pump repair.
- Downflow furnace in a manufactured home. Covered in its own section below.
Common sizes are 5, 10, 15 and 20 kW, built from elements of about 5 kW each, so a 15 kW furnace typically has three elements that switch on separately. Every kilowatt produces about 3,412 Btu per hour, which puts a 10 kW kit at roughly 34,000 Btu/h.
The parts that make electric heat work
- Elements. Coils of resistance wire strung through ceramic insulators on a metal frame.
- Sequencers or relays. They bring elements on one at a time, staggered by seconds to about a minute, so your electrical service doesn't take the whole load at once. Older systems use heat-activated sequencers; newer air handlers often use relays run by a control board. In some electric furnaces, the first stage also starts the blower.
- Limit switches. Each element typically has an automatic-reset limit that opens if the air around it gets too hot, usually because airflow has dropped, and closes again once it cools.
- Thermal fuses (fusible links). A one-time backup to the limit. Once it opens, it stays open until it's replaced.
- Breakers and lugs. Electric heat runs on its own 240-volt breaker, and larger air handlers often have built-in breakers for each heating circuit. The lugs where the heavy wires land have to stay tight, because at this much current a slightly loose connection heats up.
Common electric heat failures
A burnt-out element
A broken element stops heating. On a 15 kW furnace with three elements, losing one leaves you with two-thirds of your heat, so the air is still warm and the house falls behind on cold days. We confirm it two ways: a resistance reading (a healthy 5 kW, 240-volt element measures roughly 11 to 12 ohms, and a burnt one reads open) and the amp draw on each circuit.
A failed sequencer or relay
A sequencer that won't close leaves a perfectly good element cold, which is why replacing the element alone doesn't always fix lukewarm air. The more dangerous failure is a sequencer whose contacts stick closed. The elements keep heating after the thermostat is satisfied, the limits start cycling, and you may notice the blower running long after it should have stopped, or a hot smell at the vents.
A limit that keeps tripping
Limits trip on heat, and heat builds when airflow drops. Clogged filter, weak blower motor, closed supply vents, blocked return, crushed duct: any of them will do it. Every trip cycles the element hot and cold, and enough of them eventually open the thermal fuse. A new fuse with the same bad airflow just sets up the next failure, so start with the filter (see how often to change your air filter).
A breaker that trips
Timing tells us a lot. A breaker that trips the moment the heat comes on usually means a short, such as a broken element touching the frame or damaged wiring. If it trips after running for a while, look for overheating: a loose or burnt lug, a breaker worn out by years of heavy load, or wiring that was undersized from the start.
Burnt or loose lugs
A loose connection under heavy current turns into a heater of its own. Inside the panel or air handler it shows up as darkened or melted insulation and discolored metal; from the outside, you usually only notice a sharp electrical smell or a breaker that trips partway through a cycle. This is the failure that starts fires. The repair is cutting back to clean conductor, replacing the damaged lug or breaker, and tightening the connection to the manufacturer's specification.
What electric heat costs to run
The math is simple: kW × hours running × your rate per kWh = cost. Resistance heat turns every kilowatt-hour into the same 3,412 Btu, whatever the weather. The table below uses an example rate of 15¢ per kWh. That's a round number for illustration; your actual rate is on your bill.
| Heat size | Current at 240 V | Heat output | Cost per hour at an example 15¢/kWh |
|---|---|---|---|
| 5 kW | about 21 A | about 17,000 Btu/h | $0.75 |
| 10 kW | about 42 A | about 34,000 Btu/h | $1.50 |
| 15 kW | about 63 A | about 51,000 Btu/h | $2.25 |
| 20 kW | about 83 A | about 68,000 Btu/h | $3.00 |
A worked example at that same hypothetical rate: a 15 kW electric furnace that runs 8 hours on a cold day uses 15 × 8 = 120 kWh. At 15¢ per kWh, that's $18 for the day, or about $126 for a week of similar weather. To use your own number, divide your total bill by the kilowatt-hours on it, so delivery charges and fees are included.
A heat pump in mild weather delivers the same heat for roughly a third to half the electricity. In a heat pump system, the strips should only ever be backup. And if you heat with an electric furnace and your air conditioner is due for replacement, look at heat pump installation before you replace like for like.
First-use smell or a real problem
The first time electric heat runs each fall, summer dust on the elements burns off. That dusty, slightly scorched smell should fade within the first hour or so and stay gone. Our heating maintenance page covers that first run of the season. Treat the smell as a real problem if:
- it's sharp, like hot plastic or electrical insulation, rather than dusty
- it returns every time the heat comes on, weeks into the season
- it comes with a tripped breaker, dimming lights or a buzzing air handler
- it's strongest near the electrical panel or the air handler's disconnect
Turn the system off at the thermostat, switch off its breaker and call us. If you see smoke or flame, get everyone out of the house and call 911.
Manufactured homes and downflow electric furnaces
Many manufactured homes heat with a downflow electric furnace in a hallway closet. Air comes in through the louvered closet door or a grille, passes over the elements and blows down into ducts under the floor. These furnaces are often 15 or 20 kW, and the AC coil frequently sits in the same cabinet. Most of what goes wrong traces back to that layout:
- A starved return. Storage in the closet, furniture against the louvers or a solid replacement door cuts the airflow, and the limits start tripping. Keep the door grille clear.
- A filter that's easy to forget. Usually behind the closet door, often at the top of the cabinet, out of sight.
- Ducts under the floor. They can tear, disconnect or get crushed, and warm air disappears under the home. Our ductwork repair page covers the fixes.
- Equipment that isn't interchangeable. Furnaces built for manufactured homes have cabinet sizes and floor connections a standard air handler doesn't match, so a replacement should be a unit designed for manufactured-home installation.
What you can safely check, and what to leave alone
You can:
- confirm the thermostat is set to Heat and calling for heat
- replace a dirty filter and clear blocked vents or return grilles
- reset a tripped heat breaker once, and leave it off if it trips again
Leave everything else to a licensed technician. The terminals inside an air handler stay live even with the thermostat off, and this wiring carries enough current to cause serious burns or a fire. Never install a larger breaker to stop trips. Never bypass a limit or thermal fuse to get heat back, either; those parts are what keep a hot element from starting a fire. When we come out, you get the cause and a written price before we start, and the repair carries our 30-day repair warranty.