A North Texas furnace spends most of the year switched off, or running only its blower for the AC, while attic dust, insects and summer heat get to it. Then the first cold night comes and it has to light on the first try. Our fall tune-up goes in a fixed order. We check that it burns and vents safely, then that it will light every time, and only then how efficiently it runs. Here's what that covers on gas furnaces, heat pumps and electric heat.
Safety first: the gas furnace checks that matter most
Carbon monoxide, before anything runs
We take CO readings in the living space when we arrive, then near the furnace and water heater, and again at the supply registers once the burners are lit. The first reading is the baseline. If the number climbs after the furnace fires, that's where we start.
Combustion analysis
An analyzer probe goes into the flue (through a small test port in the metal vent on an 80% furnace, or the manufacturer's test port on a 95%) and reads oxygen, carbon monoxide and flue temperature. From those numbers we can tell whether the burners are getting the right mix of gas and air. High flue CO usually comes down to dirty burners, wrong gas pressure, starved combustion air or a venting problem. We'd much rather find it in the flue than in your house.
Heat exchanger inspection
We run a light and an inspection camera through the burner and flue openings to look for cracks, rust-through and soot. Then we watch the flame as the blower kicks on. If it jumps or rolls right then, we look harder. Our furnace repair page explains how a suspected crack gets confirmed.
Venting and combustion air
On an 80% furnace: every joint in the metal vent fastened and sealed, an upward pitch, clearance from wood and insulation, an intact cap and a draft check. On a 95% furnace: PVC joints, supports and slope, outdoor terminations clear, and the condensate trap removed, flushed and refilled. For closet furnaces, we confirm the combustion-air openings haven't been blocked or painted over.
Gas pressure and burners
We measure gas pressure at the valve with a manometer and set it to the rating plate, then clean and align the burners. Over a summer, rust flakes, attic dust and the occasional spider web settle in burner openings and throw the flame off.
Safety switches
We test the high-limit and flame rollout switches, plus the pressure switch and its hoses. These are what shut a furnace down when something goes wrong. We check that each one still would.
Then the parts that decide whether it lights
Once it's safe, we move on to the parts behind most no-heat calls on the first cold night:
- Flame sensor cleaned and its signal measured in microamps. A reading that barely passes in October can drop out in January.
- Hot-surface igniter checked for hairline cracks and measured.
- Inducer motor checked for bearing noise and current draw.
- Blower current compared with the motor's rating, the capacitor tested, and the blower wheel checked for buildup.
- Temperature rise measured across the furnace and compared with the range on its rating plate.
- A full heating cycle run from the thermostat, start to finish, with the filter checked along the way.
Heat pumps and electric heat get their own checklist
A heat pump heats with parts that sit idle all summer, so its fall visit looks different:
- Defrost test. We force a defrost cycle and watch the reversing valve shift, the outdoor fan stop, backup heat come on and the coil clear. Then we make sure the system goes back to heating.
- Reversing valve shifting cleanly into heat mode, checked with line temperatures for internal leak-by.
- Outdoor coil clean, with leaves cleared and room around the base for defrost water to drain away.
- Refrigerant operating pressures and temperatures checked in heat mode.
- Heat strips: current draw on each element to prove every stage heats, sequencer or relay staging, strip limit switches, and breaker lugs and wiring checked for heat discoloration.
- Thermostat settings for auxiliary heat, so the strips don't run when the heat pump can carry the load alone.
The same strip checks apply to electric furnaces, including those in manufactured homes. If you're already seeing lukewarm air or a jump in winter bills, our heat pump repair page explains what's normal and what isn't.
Book it before the first norther
The National Weather Service puts the average first freeze at DFW Airport around November 22, and the first front cold enough to send you to the thermostat usually shows up before that. Book for September, October or early November, before a weak igniter becomes a no-heat call.
Two timing tips. Run the heat yourself on a cool October afternoon, so any smell, noise or failure shows up while it's still mild outside. And if you're on a twice-a-year schedule, the spring visit is a different job. Our AC maintenance checklist covers that one.
That burning smell on the first cold night
The first time the heat runs each season, a dusty, slightly burnt smell is normal: dust that settled on the heat exchanger or heat strips over summer is burning off. Other smells deserve attention.
| Smell | What it usually means | What to do |
|---|---|---|
| Dusty, burnt odor on the season's first run | Summer dust burning off | Normal. It should fade within the first hour or so of running. |
| Rotten eggs or sulfur | Possible gas leak | Leave the house and call 911 and your gas utility from outside. Full steps are on our emergency heating page. |
| Hot plastic or electrical burning that doesn't fade | An overheating motor, wire or control | Turn the system off at the thermostat and book a repair. |
| Sharp, acrid or exhaust-like odor; stinging eyes | Combustion gases not venting properly | Turn the furnace off, open windows and check your CO alarms. If one sounds, get out and call 911. |
| A burning smell with every cycle, all season | Something touching a hot surface, or debris in the burners | Turn it off and book a repair. |
Safety checks you can do yourself
- CO alarms. Press the test button monthly, check the replace-by date on the back, and make sure there's one outside each sleeping area and on every level. Plug-in models should have a battery backup.
- Nothing stored in the furnace closet. Boxes and clothes block airflow and add fuel for a fire. Paint, gasoline and solvents don't belong near any gas appliance, and vapors from bleach or pool chemicals get drawn into the burners, where they form acids that corrode the heat exchanger.
- Combustion air. Keep louvered closet doors and grilles open; a solid replacement door can starve the burners of air.
- Attic clearance. Stored items and loose insulation stay away from the furnace and its vent pipe. Keep a clear path to the unit, too, so we can get to it.
- Outdoor vent pipes. On a 95% furnace, keep the PVC pipes outside clear of leaves, mulch, shrubs and wasp nests.
- Filter. Start the season with a fresh one; our guide on how often to change your air filter covers timing and MERV ratings.
- Panels on. Furnace doors in place and latched. The burner compartment is built to run closed.
What you get afterward
You get a written summary of what we found, with the readings we took: CO levels, combustion numbers, gas pressure, temperature rise and flame signal. Next fall, we compare against them. If anything needs repair, we tell you how urgent it is and give you a written price before any work starts. A part that's starting to wear can usually wait for a convenient day. A CO problem or a cracked heat exchanger can't.